GIS Product Catalogue

SYSTEM COMPARISON

Feature

No Flow

Low Flow Controlled Flow

High Pressure

Recirculation

No

Yes

Yes

Yes

Pneumatic control of two pressure environments

Pneumatic control of two pressure environments

Recirculation control

No

Gravity driven

Asymmetric pressure control

No

No

Yes

Yes

Max inlet pressure Max outlet pressure

0

0

0

400mb

-200mb

-200mb

-200mb

-400mb

± 2mb typical

± 2mb typical

± 2mb typical

± 2mb typical

Meniscus stability

Degassing (optional)

No

Yes

Yes

Yes

No (heater mats as active insulation optional)

No (heater mats as active insulation optional)

20W heater mats 50W heater car tridge

Header tank heating (optional)

20W heater mats

UV, Aq, Oil, Functional fluids*

UV, Aq, Oil, Functional fluids*

UV, Aq, Oil, Functional fluids*

UV, Aq, Oil, Functional fluids*

Fluids supported

Atlas GUI, Customer own (CoAP), Telnet

Atlas GUI, Customer own (CoAP), Telnet

Atlas GUI, Customer own (CoAP), Telnet

Atlas GUI, Customer own (CoAP), Telnet

System interface

System connection

RJ45

RJ45

RJ45

RJ45

Power supply

24V DC

24V DC

24V DC

24V DC

* Based upon materials compatibility